What can you do with Alpha Innotec and Niko Home Control?

Optimise energy consumption of your heat pump

If you connect your heat pump or heat pump boiler via Smart Grid Ready contacts to Niko Home Control, you can use energy routines to optimise energy consumption.

You can perform the following routines:

  • Solar mode, to benefit from excess solar energy

  • Peak mode, to avoid peak consumption

We recommend the following options to make even better use of this connection:

Get a complete overview of the energy flows in your home, including your self-consumption; see https://guide.niko.eu/en/umnhc2/lv/energy-insights.

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:

Required additional products

Reference numbers

Connected controller

Switching module with two outputs

550-00103 or

550-00106

Connected controller with a wireless bridge

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721X2

Wireless smart hub

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721X2

Alpha Innotec requirements

Your system meets the following requirements:

  • It is a heat pump or heat pump boiler with Smart Grid Ready contacts.

  • It is configured to allow correct Smart Grid Ready contact use.

Your system is one of the following Alpha Innotec products*:

Potential-free contacts

230 V contacts

Brine-to-water heat pumps

  • SW H3

  • SWC(V) H1/H3

  • WZS(V) H3

  • PWZSV H1/H2/H3

-

Air-to-water heat pumps

  • LWCV

  • LWDV

  • LW(A)V

  • LW(A)HV

  • LWAV+

  • Paros

  • Hybrox

  • LWP

-

Heat pump boilers

  • METROAIR AQUA 201(S) 190 liter

  • METROAIR AQUA 301(S) 260 liter

  • METRO Microbooster V 190

  • METRO Microbooster P 190

  • METRO Microbooster V 260 

-

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Connecting heat pumps

Via potential-free contacts:

Switching module

Connected double switch

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

Smart Grid 1 and 2 (as indicated in the wiring diagrams) correspond to the the following Smart Grid Ready contacts on your heat pump:

 

Smart Grid 1

Smart Grid 2

Alpha Innotec brine-to-water heat pumps

X4-X5 (L1- in5)

X4-X5 (L1- in6)

Alpha Innotec air-to-water heat pumps

X4-X3-2 (L1- in3)

X4-X3-2 (L1- in4)

Alpha Innotec heat pump boilers

QA1 (SG1-GND)

QA1 (SG2-GND)

Programming energy-saving routines for heat pumps

Configure the energy-saving routines for the heat pump via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/solar-mode and https://guide.niko.eu/en/smnhc2/lv/peak-mode.

You can use the following programming example as inspiration or as a starting point: https://guide.niko.eu/en/penhc2/lv/making-a-bosch-heat-pump-respond-to-excess-electri

It is advised to configure the parameters as follows:

Solar mode

  • Level of excess solar energy that activates the device (one of the following options):

    • 50 % of the power of the heat pump compressor

    • 25 % of the thermal capacity of the heat pump (often the name of the heat pump contains a reference to this thermal capacity)

  • Minimum activation duration: 1 hour

Optionally: Define the latest start time and duration to ensure that the device is activated before the peak hours.

Peak mode

  • Maximum power consumption (one of the following options):

    • 100 % of the heat pump compressor power

    • 50 % of the thermal capacity of the heat pump (often the name of the heat pump contains a reference to this thermal capacity)

  • Peak target value: the maximum power level that should trigger the devices to turn off

  • Peak mode type:

    • Predictive (capacity tariff in Flanders)

    • Direct

Niko routine

Smart Grid Ready status

Smart Grid Ready output contact

Setting

Solar mode

Forced on

Smart Grid Ready 1

On (closed)

Smart Grid Ready 2

On (closed)

Enhanced comfort

Smart Grid Ready 1

Off (open)

Smart Grid Ready 2

On (closed)

Peak mode

Forced off

Smart Grid Ready 1

On (closed)

Smart Grid Ready 2

Off (open)

Normal mode

Normal operation

Smart Grid Ready 1

Off (open)

Smart Grid Ready 2

Off (open)