What can you do with FireAngel and Niko Home Control?

Get a notification when smoke or heat is detected

If you connect your smoke detector to Niko Home Control, you can get a notification when smoke or heat is detected. You will be informed via the Niko Home app on a tablet or smartphone and/or the Touchscreen.

We recommend the following options to make even better use of this connection:

Automatically switch on lighting and switch off ventilation, when smoke is detected; see https://guide.niko.eu/en/smnhc2/lv/custom-routine.

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:

Required additional products

Reference numbers

Connected controller

Digital potential-free sensor module with one free input per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not potential-free, you need an additional potential-free contact module (e.g. Finder 22.32.0.230.1xx0 for 230 V connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

550-00210

Connected controller with a wireless bridge

Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721x1, 552-721x2

Wireless smart hub

Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721x1, 552-721x2

FireAngel requirements

Your system meets the following requirements:

  • Your smoke detector system has a potential free or 12/24 V DC or 230 V AC output contact, at one of the following positions:

    • on the detector itself

    • on the system’s interface gateway

  • It is compatible with the Niko module (see Niko requirements).

Your system is one of the following FireAngel products* and is connected to the FireAngel WRLYM-NLB Relay:

Potential-free contact

Smoke detectors

  • SM-F-1EU

  • HM-F-1EU

  • ST-630

  • HT-630

  • NM-C0-10X

*Consult the website of the supplier for detailed specifications and the latest products.

All FireAngel smoke detectors with WiSafe 2 technology can be connected to the FireAngel WRLYM-NLB Relay.

Wiring diagrams

Connecting the sensor module

Via potential-free output contact

Connect contact 1 on the Niko sensor module to the output on the third-party system, as shown in the wiring diagram.

Common

Contact 1

FireAngel smoke detector

Potential-free contacts on the WRLYM-NLB Relay

Connecting the connected switch

Via potential-free output contact

If the contacts of your ventilation system are not 230 V, you additionally need an appropriate potential-free contact module.

Connect contact 1 on the Niko connected switch to the output on the third-party system, as shown in the wiring diagram.

*230 V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

Common

Contact 1

FireAngel smoke detector

Potential-free contacts on the WRLYM-NLB Relay

Programming

Configure the potential-free sensor module or connected switch and create a push notification via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/creating-notifications .