FireAngel
What can you do with FireAngel and Niko Home Control?
Get a notification when smoke or heat is detected
If you connect your smoke detector to Niko Home Control, you can get a notification when smoke or heat is detected. You will be informed via the Niko Home app on a tablet or smartphone and/or the Touchscreen.
We recommend the following options to make even better use of this connection:
Automatically switch on lighting and switch off ventilation, when smoke is detected; see https://guide.niko.eu/en/smnhc2/lv/custom-routine.
What do you need?
Niko requirements
Your Niko Home Control installation meets the following requirements:
It has a wireless smart hub or a connected controller II.
It is configured with the most recent programming software.
Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:
Required additional products | Reference numbers | |
---|---|---|
Connected controller | Digital potential-free sensor module with one free input per signal that you want to use in Niko Home Control If the output contact on your third-party device is not potential-free, you need an additional potential-free contact module (e.g. Finder 22.32.0.230.1xx0 for 230 V connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) | |
Connected controller with a wireless bridge | Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950) | |
Wireless smart hub | Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections) The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950) |
FireAngel requirements
Your system meets the following requirements:
Your smoke detector system has a potential free or 12/24 V DC or 230 V AC output contact, at one of the following positions:
on the detector itself
on the system’s interface gateway
It is compatible with the Niko module (see Niko requirements).
Your system is one of the following FireAngel products* and is connected to the FireAngel WRLYM-NLB Relay:
Potential-free contact | |
---|---|
Smoke detectors |
|
*Consult the website of the supplier for detailed specifications and the latest products.
All FireAngel smoke detectors with WiSafe 2 technology can be connected to the FireAngel WRLYM-NLB Relay.
Wiring diagrams
Connecting the sensor module
Via potential-free output contact
Connect contact 1 on the Niko sensor module to the output on the third-party system, as shown in the wiring diagram.

Common | Contact 1 | |
---|---|---|
FireAngel smoke detector | Potential-free contacts on the WRLYM-NLB Relay |
Connecting the connected switch
Via potential-free output contact
If the contacts of your ventilation system are not 230 V, you additionally need an appropriate potential-free contact module.
Connect contact 1 on the Niko connected switch to the output on the third-party system, as shown in the wiring diagram.

*230 V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)
Common | Contact 1 | |
---|---|---|
FireAngel smoke detector | Potential-free contacts on the WRLYM-NLB Relay |
Programming
Configure the potential-free sensor module or connected switch and create a push notification via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/creating-notifications .