Skip to main content
Skip table of contents

Custom routine

What is the Custom routine?

The routine Custom routine is a non-predefined routine to carry out the Niko Home Control programming. If you do not find a suitable option amongst the existing routines, you can create one yourself with the Custom routine.
A Custom routine puts one or more devices in a fixed configured state. If you press the connected push button, the start behaviour of the routine will be activated. If you press the push button again, the stop behaviour of the routine will be activated.

Starting point

  • You have created, for instance, the following controls and devices:

    • a ventilator system

    • a push button with LED

    • a switched lighting circuit

    • all devices you wish to use in this routine.

  • You are in the Create overview window.

Procedure

  1. In the right-hand button bar, click on the Routine button.
    Result:
    The Routine pane appears.

  2. Choose the room as follows:

    • Choose Room from the drop-down list.

    • Click on the room in the drawing area or select it from the drop-down list. 

  3. Click on the arrow next to the category  Free function.

  4. Click on Custom routine.

  5. Give the routine a name.

  6. Set the behaviour as follows:

    BehaviourWhat?How?
    AChoose the control(s) with which you want to start and stop the routine.

    Click on the plus signs of the controls you want to include in the routine.

    BChoose the devices you want to control with the control(s) from behaviour A.

    1 Click on the plus signs of the devices.
    In this example, we use a switched lamp and a ventilation system.

    2 Under START, you can define the behaviour a device must display when the routine starts, or you can reuse a device.
    In this example, we switch on the lamp and put the ventilation system in the highest position.

    3 Under STOP, you can define the stop behaviour of each device.
    In this example, the lamp will be switched off immediately and the ventilation system will switch to medium speed after ten minutes.


  7. Under Parameters, set the following:

    ParameterChoiceDescriptionExample
    Behaviour of the indication LED

    The LED and/or app icon is illuminated:
    -when all devices from behaviour B have adopted the value of the start behaviour.
    -when the routine is started.




    Feedback when the start behaviour is active

    Text


    Add the text here that you wish to see with the app icon. 
    Max. 20 characters
    Standard text: Activated
    Feedback wwhen the start behaviour is not active

    Text


    Add the text here that you wish to see with the app icon. 
    Max. 20 characters
    Standard text: Deactivated
    Stop the routine automatically after a specific time periodOn/off
    1 min. - 23 h. 59 min. 59 sec.

    When the parameter is set to "ON", the routine is deactived after the time set and the stop behaviour is executed.

    Start the routine automatically after a predefined period of timeOn/off
    1 min. - 23 h. 59 min. 59 sec.

    When the routine is active and the parameter is set to "ON", the start behaviour is repeated after the time set as long as the routine is active.

At least one control or device is required for both behaviour A and behaviour B. If you do not add this control or device, the routine symbol will show a warning. Underneath the behaviour, the following message will be displayed: you have to add at least one control or device to complete the routine.

Video

Have a look at an example here. Turn on the sound to watch the video.

https://www.youtube.com/embed/1HZjvMYsgrk


JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.