Skip to main content
Skip table of contents

Systemair

What can you do with Systemair and Niko Home Control?

Manage multi-zone ventilation

If you connect your ventilation units to Niko Home Control, you can control them via push buttons, the Niko Home app on a tablet or smartphone, the Touchscreen and/or Digital black.

You can control multiple rooms individually, using the following actions:

  • Set fan speed: low, medium, high

  • Activate boost (temporary high fan speed)

We recommend the following options to make even better use of this connection:

  • Automate ventilation speeds based on air quality conditions measured by push buttons with comfort sensors; see Creating a condition.

  • Use excess solar energy for heat recuperation (using the by-pass function of your ventilation system), via solar mode.

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the type of contacts on your ventilation system, you need one of the following additional products for each ventilation zone:

Required additional product

Reference numbers

Two or three contacts to set different speeds

Ventilation module

550-00140

One 0 – 10 V contact

Analogue control module

550-00240

If you are using wireless interaction devices for your ventilation system (e.g., buttons), the wireless bridge is strictly necessary.

Systemair requirements

Your system meets the following requirements:

  • It is a ventilation system C or D.

  • Your ventilation device can be controlled in at least one of the following ways:

    • Via two or three contacts to set different speeds

    • Via one 0 – 10 V contact

  • It is compatible with the Niko module (see Niko requirements).

Your system is one of the following Systemair products*:

The table shows the relevant contacts that are present on each product. If a type of contact is not present, it is shown as “-”.

Two or three contacts to set different speeds

One 0 – 10 V contact

Save VTC 200

-

GND/AI3

Save VTC 300

Save VTC 500

Save VTC 700

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Consult the manufacturer’s manual for the full installation procedure and the necessary settings.

Connecting the analogue control module

Connect contact 1 on the Niko analogue control module to the 0 – 10 V contact on the ventilation system, as shown in the wiring diagram.

Wiring

Programming

Configure the ventilation module or analogue control module via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/creating-a-control-or-a-device

You need to set the boost time. In the case of an analogue control module, you also have to define the voltage for the three fan speeds.