Aqualeak

What can you do with Aqualeak and Niko Home Control?

Get a notification when water leakage is detected

If you connect your water leakage sensor to Niko Home Control, you can get a notification when water is detected. You will be informed via the Niko Home app on a tablet or smartphone and/or the Touchscreen.

We recommend the following options to make even better use of this connection:

Close the water valve automatically when water leakage is detected, see Creating a condition.

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:

Required additional products

Reference numbers

Connected controller

Digital potential-free sensor module with one free input per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not potential-free, you need an additional potential-free contact module (e.g. Finder 22.32.0.230.1xx0 for 230 V connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

550-00210

Connected controller with a wireless bridge

Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721x1, 552-721x2

Wireless smart hub

Connected (double) switch with one free input (E) per signal that you want to use in Niko Home Control

If the output contact on your third-party device is not 230 V, you need an additional 230 V contact module (e.g. Finder 22.32.0.230.1xx0 for potential-free connections, Finder 22.32.0.012.1xx0 for 12 V DC connections, Finder 22.32.0.024.1xx0 for 24 V DC connections)

The connected (double) switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721x1, 552-721x2

Aqualeak requirements

Your system meets the following requirements:

  • Your water leakage sensor has a potential free or 12/24 V DC or 230 V AC output contact.

  • It is compatible with the Niko module (see Niko requirements).

Your system is one of the following Aqualeak products*:

 

Potential-free contact

230 V contact

12/24 V contact

Water leakage detectors

  • EMS1

  • EMS5

  • EMS10

  • EMS1

  • EMS1

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Connecting the sensor module

Via potential-free output contact

Connect contact 1 on the Niko sensor module to the output on the third-party system, as shown in the wiring diagram.

 

Potential-free output contact

Aqualeak EMS1

Alarm relay 1 (NO/COM)

Aqualeak EMS5 and EMS10

Alarm relay (NO/COM)

Via 230 V or 12/24 V output contact

If the contacts of your ventilation system are not potential-free, you additionally need an appropriate potential-free contact module.

Connect contact 1 on the Niko sensor module to the output on the third-party system, as shown in the wiring diagram.

230 V output contact

12/24 V output contact

Wiring

*230 V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

Wiring

*12 V to potential-free contact module (e.g. Finder 22.32.0.012.1xx0) or 24 V to potential-free contact module (e.g. Finder 22.32.0.024.1xx0)

 

230 V output contact

12/24 V output contact

Aqualeak EMS1

DC OUT

Alarm relay 1 (NO/COM)

Connecting the connected switch

Via potential-free output contact

If the contacts of your ventilation system are not 230 V, you additionally need an appropriate potential-free contact module.

Connect contact 1 on the Niko connected switch to the output on the third-party system, as shown in the wiring diagram.

*230 V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

 

Potential-free output contact

Aqualeak EMS1

Alarm relay 1 (NO/COM)

Aqualeak EMS5 and EMS10

Alarm relay (NO/COM)

Via 230 V or 12/24 V output contact

If the contacts of your ventilation system are not 230 V, you additionally need an appropriate contact module.

Connect contact 1 on the Niko connected switch to the output on the third-party system, as shown in the wiring diagram.

230 V output contact

12/24 V output contact

*12 V to 230 V contact module (e.g. Finder 22.32.0.012.1xx0) or 24 V to 230 V contact module (e.g. Finder 22.32.0.024.1xx0)

 

230 V output contact

12/24 V output contact

Aqualeak EMS1

DC OUT

Alarm relay 1 (NO/COM)

Programming

Configure the potential-free sensor module or connected switch and create a push notification via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/creating-notifications .