CTC: Energy optimisation via wired connection (SG Ready contacts)

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:

Required additional products

Reference numbers

Connected controller

Switching module with two outputs

550-00103 or 

550-00106

Connected controller with a wireless bridge

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder

(e.g. Legrand 412950)

552-721X2

Wireless smart hub

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder

(e.g. Legrand 412950)

552-721X2

CTC requirements

Dit system opfylder følgende krav:

  • Det er en varmepumpe eller varmepumpekedel med Smart Grid forberedte kontakter.

  • Det er konfigureret til korrekt anvendelse af Smart Grid forberedt kontakt.

  • Your system contains one of the following CTC logic boards*:

    • EcoLogic M

    • EcoLogic L

    • EcoZenith i360

    • EcoZenith i555 Pro

Your system is one of the following CTC products*:

Potential-free contacts

230 V contacts

Heat pumps

  • EcoAir 700

  • EcoAir 600

  • EcoAir 400

  • EcoPart 600

  • EcoPart 400

  • Gsi 600 (combi)

-

Heat pump boilers

  • WaterHeater 101, only heat pump (395W)

  • WaterHeater 101, only resistor (2000W)

  • WaterHeater 101, heat pump and resistor (2395W)

  • WaterHeater 201-Inox, only heat pump (569W)

  • WaterHeater 201-inox, only resistor (2000W)

  • WaterHeater 201-Inox, heat pump and resistor (2569W)

-

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Connecting heat pumps

Via potentialfri kontakter:

Relæmodul

Smart dobbeltafbryder

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V til potentialfri kontaktmodul (f.eks. Finder 22.32.0.230.1xx0)

Smart Grid 1 and 2 (as indicated in the wiring diagrams) correspond to the the following Smart Grid Ready contacts on your heat pump:

Smart Grid 1

Smart Grid 2

Option 1 for CTC heat pump

A14 and A25 (relay K22)

A24 and A25 (relay K23)

Option 2 for CTC heat pump

G33 and G34 (relay K24)

G73 and G74 (relay K25)

Connecting heat pump boilers

Heat pump boilers usually have only one photovoltaic contact. You only have to connect the Smart Grid Ready 2.

Via potentialfri kontakter:

Relæmodul

Smart dobbeltafbryder

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V til potentialfri kontaktmodul (f.eks. Finder 22.32.0.230.1xx0)

Smart Grid 2 (as indicated in the wiring diagrams) corresponds to the the following Smart Grid Ready contact on your heat pump boiler:

Smart Grid 2

CTC heat pump boiler

CN6/5-6

Programming energy-saving routines for heat pumps

Konfigurer de energibesparende programmeringer til varmepumpen via Niko Home Control programmeringssoftware. For yderligere oplysninger henvises til https://guide.niko.eu/en/smnhc2/lv/solar-mode og https://guide.niko.eu/en/smnhc2/lv/peak-mode.

Du kan anvende følgende programmeringseksempel som en inspiration eller som et udgangspunkt: https://guide.niko.eu/en/penhc2/lv/making-a-bosch-heat-pump-respond-to-excess-electri

Det anbefales at konfigurere parametrene som følger:

Solcellefunktion

  • Niveau af overskydende solenergi, der aktiverer enheden (en af følgende muligheder):

    • 50 % af varmepumpens kompressoreffekt

    • 25 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Minimum aktiveringsvarighed: 1 time

Valgfrit: Definer det seneste starttidspunkt og varighed for at sikre, at enheden aktiveres før spidsbelastningstidspunktet.

Spidsbelastningsfunktion

  • Maksimalt effektforbrug (en af følgende muligheder):

    • 100 % af varmepumpens kompressoreffekt

    • 50 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Maksimal målværdi: Det maksimale strømniveau, der bør få enhederne til at slukke

  • Type spidsbelastningsfunktion:

    • Prædiktiv (kapacitetstarif i Flandern)

    • Direkte

Niko programmering

Smart Grid forberedt status

Smart Grid forberedt udgangskontakt

Indstilling

Solcellefunktion

Forceret tænd

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Tændt (lukket)

Mere komfort

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Tændt (lukket)

Spidsbelastningsfunktion

Forceret sluk

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Slukket (åben)

Normal funktion

Normal funktion

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Slukket (åben)