Niko Home Control is evolving into MOTIV Building Control. MOTIV is a new brand for intelligent building automation. Built on the trusted foundation of Niko Home Control, MOTIV solutions are designed to make buildings work more naturally for the people inside them. MOTIV helps professionals create smarter, more comfortable buildings. With technology that works quietly in the background. All existing Niko Home Control solutions remain fully compatible with MOTIV. Over time, the full portfolio will move to the MOTIV brand. Discover MOTIV at niko.eu/MOTIV
Connections to Third-Party Systems
English Danish Dutch French German Slovak Swedish Polish
English Danish Dutch French German Slovak Swedish Polish

Alpha Innotec

Dette kan du gøre med Alpha Innotec og Niko Home Control?

Optimere din varmepumpes energiforbrug

Hvis du forbinder din varmepumpe eller varmepumpekedel med Niko Home Control via Smart Grid forberedte kontakter, kan du anvende energiprogrammeringer til at optimere energiforbruget.

Du kan udføre følgende programmeringer:

  • Solcellefunktion, for at udnytte overskydende solenergi

  • Spidsbelastningsfunktion, for at undgå spidsbelastningsforbrug

Vi anbefaler følgende muligheder for at udnytte denne integration optimalt:

Få et komplet overblik over energistrømmene i din bolig, inklusive dit egetforbrug på https://guide.niko.eu/en/umnhc2/lv/energy-insights.

Du skal bruge:

Niko-krav

Din Niko Home Control installation opfylder følgende krav:

Afhængigt af grundmodulerne i din Niko Home Control installation skal du installere følgende ekstra produkter:


Påkrævede ekstra produkter

Referencenumre

Controller

Relæmodul med to udgange

550-00103 eller

550-00106

Controller med en trådløs bridge

Smart dobbeltafbryder

Den smarte afbryder kan placeres på en DIN-skinne ved hjælp af et beslag

(f.eks. Legrand 412950)

552-721X2

Trådløs smart hub

Smart dobbeltafbryder

Den smarte afbryder kan placeres på en DIN-skinne ved hjælp af et beslag

(f.eks. Legrand 412950)

552-721X2

Alpha Innotec krav

Dit system opfylder følgende krav:

  • Det er en varmepumpe eller varmepumpekedel med Smart Grid forberedte kontakter.

  • Det er konfigureret til korrekt anvendelse af Smart Grid forberedt kontakt.

Dit system er et af følgende Alpha Innotec produkter*:


Potentialfri kontakter

230 V kontakter

Havvand-til-vand varmepumper

  • SW H3

  • SWC(V) H1/H3

  • WZS(V) H3

  • PWZSV H1/H2/H3

-

Luft-til-vand varmepumper

  • LWCV

  • LWDV

  • LW(A)V

  • LW(A)HV

  • LWAV+

  • Paros

  • Hybrox

  • LWP

-

Varmepumpekedler

  • METROAIR AQUA 201(S) 190 liter

  • METROAIR AQUA 301(S) 260 liter

  • METRO Microbooster V 190

  • METRO Microbooster P 190

  • METRO Microbooster V 260

-

*Se leverandørens websted for detaljerede oplysninger og de nyeste produkter.

Forbindelsesskemaer

Tilslutning af varmepumper

Via potentialfri kontakter:

Relæmodul

Smart dobbeltafbryder

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V til potentialfri kontaktmodul (f.eks. Finder 22.32.0.230.1xx0)

Smart Grid 1 og 2 (som vist i tilslutningsskemaerne) korresponderer med de følgende Smart Grid ready kontakter på din varmepumpe:


Smart Grid 1

Smart Grid 2

Alpha Innotec havvand-til-vand varmepumper

X4-X5 (L1- in5)

X4-X5 (L1- in6)

Alpha Innotec luft-til-vand varmepumpe

X4-X3-2 (L1- in3)

X4-X3-2 (L1- in4)

Alpha Innotec varmepumpekedler

QA1 (SG1-GND)

QA1 (SG2-GND)

Programmering af energibesparende programmeringer til varmepumper

Konfigurer de energibesparende programmeringer til varmepumpen via Niko Home Control programmeringssoftware. For yderligere oplysninger henvises til https://guide.niko.eu/en/smnhc2/lv/solar-mode og https://guide.niko.eu/en/smnhc2/lv/peak-mode.

Du kan anvende følgende programmeringseksempel som en inspiration eller som et udgangspunkt: https://guide.niko.eu/en/penhc2/lv/making-a-bosch-heat-pump-respond-to-excess-electri

Det anbefales at konfigurere parametrene som følger:

Solcellefunktion

  • Niveau af overskydende solenergi, der aktiverer enheden (en af følgende muligheder):

    • 50 % af varmepumpens kompressoreffekt

    • 25 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Minimum aktiveringsvarighed: 1 time

Valgfrit: Definer det seneste starttidspunkt og varighed for at sikre, at enheden aktiveres før spidsbelastningstidspunktet.

Spidsbelastningsfunktion

  • Maksimalt effektforbrug (en af følgende muligheder):

    • 100 % af varmepumpens kompressoreffekt

    • 50 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Maksimal målværdi: Det maksimale strømniveau, der bør få enhederne til at slukke

  • Type spidsbelastningsfunktion:

    • Prædiktiv (kapacitetstarif i Flandern)

    • Direkte

Niko programmering

Smart Grid forberedt status

Smart Grid forberedt udgangskontakt

Indstilling

Solcellefunktion

Forceret tænd

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Tændt (lukket)

Mere komfort

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Tændt (lukket)

Spidsbelastningsfunktion

Forceret sluk

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Slukket (åben)

Normal funktion

Normal funktion

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Slukket (åben)