Skip to main content
Skip table of contents

Atag

What can you do with Atag and Niko Home Control?

Optimise energy consumption of your heat pump

Hvis du forbinder din varmepumpe eller varmepumpekedel med Niko Home Control via Smart Grid forberedte kontakter, kan du anvende energiprogrammeringer til at optimere energiforbruget.

Du kan udføre følgende programmeringer:

  • Solcellefunktion, for at udnytte overskydende solenergi

  • Spidsbelastningsfunktion, for at undgå spidsbelastningsforbrug

Vi anbefaler følgende muligheder for at udnytte denne tilslutning optimalt:

Få et komplet overblik over energistrømmene i din bolig, herunder dit eget forbrug; se https://guide.niko.eu/en/umnhc2/lv/energy-insights.

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Afhængigt af grundmodulerne i din Niko Home Control installation skal du installere følgende ekstra produkter:

Påkrævede ekstra produkter

Referencenumre

Controller

Relæmodul med to udgange

550-00103 eller 550-00106

Controller med en trådløs bridge

Smart dobbeltafbryder

Den smarte dobbeltafbryder kan placeres på en DIN-skinne med en modulholder (fx Legrand 412950)

552-721X2

Trådløs smart hub

Smart dobbeltafbryder

Den smarte dobbeltafbryder kan placeres på en DIN-skinne med en modulholder (fx Legrand 412950)

552-721X2

Atag requirements

Dit system opfylder følgende krav:

  • Det er en varmepumpe eller varmepumpekedel med Smart Grid forberedte kontakter.

  • Det er konfigureret til korrekt anvendelse af Smart Grid forberedt kontakt.

Your system is one of the following Atag products*:

Potential-free contacts

230 V contacts

All electric heat pumps

-

  • ATAG ENERGION M COMPACT 120 T

  • ATAG ENERGION M COMPACT 120 T 2Z

  • ATAG ENERGION M COMPACT 150 T

  • ATAG ENERGION M COMPACT 150 T 2Z

  • ATAG ENERGION M COMPACT 40

  • ATAG ENERGION M COMPACT 40 2Z

  • ATAG ENERGION M COMPACT 50

  • ATAG ENERGION M COMPACT 50 2Z

  • ATAG ENERGION M COMPACT 80

  • ATAG ENERGION M COMPACT 80 2Z

  • ATAG ENERGION M COMPACT 80 T

  • ATAG ENERGION M COMPACT 80 T 2Z

  • ATAG ENERGION M PLUS 120T + CBS 300 E

  • ATAG ENERGION M PLUS 150T + CBS 450 E

  • ATAG ENERGION M PLUS 40 + CBS 200 E

  • ATAG ENERGION M PLUS 50 + CBS 200 E

  • ATAG ENERGION M PLUS 50 + CBS 300 E

  • ATAG ENERGION M PLUS 80 + CBS 200 E

  • ATAG ENERGION M PLUS 80 + CBS 300 E

  • ATAG ENERGION M PLUS 80T + CBS 200 E

Hybride heat pumps

-

  • ATAG ENERGION M HYBRID-ALL 50 + Q25CR

  • ATAG ENERGION M HYBRID-Zone 40 + i28CZ

  • ATAG ENERGION M HYBRID-Zone 50 + i28CZ

  • ATAG ENERGION M HYBRID-Zone 50 + i28ECZ

  • ATAG ENERGION M HYBRID-Zone 80 + i36CZ

  • ATAG ENERGION M HYBRIDALL 120 T

  • ATAG ENERGION M HYBRIDALL 150 T

  • ATAG ENERGION M HYBRIDALL 40

  • ATAG ENERGION M HYBRIDALL 50

  • ATAG ENERGION M HYBRIDALL 80

  • ATAG ENERGION M HYBRIDALL 80 T

Heat pump boilers

-

  • ATAG ENERGION NUOS PLUS 200

  • ATAG ENERGION NUOS PLUS 250

  • ATAG ENERGION NUOS PLUS 250 SYS

  • ATAG ENERGION NUOS PLUS 250 TWIN SYS

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Connecting heat pumps

Via 230V kontakter:

Relæmodul

Smart dobbeltafbryder

Wiring diagram bus 230V
Wiring diagram 230V

Smart Grid 1 and 2 (as indicated in the wiring diagrams) correspond to the the following Smart Grid Ready contacts on your heat pump:

Smart Grid 1

Smart Grid 2

Atag heat pump

HV IN 1 

HV IN 2

Connecting heat pump boilers

Heat pump boilers usually have only one photovoltaic contact. You only have to connect the Smart Grid Ready 2.

Via 230V kontakter:

Relæmodul

Smart dobbeltafbryder

Wiring diagram bus 230V
Wiring diagram 230V

Smart Grid 2 (as indicated in the wiring diagrams) corresponds to the the following Smart Grid Ready contact on your heat pump boiler:

Smart Grid 1

Smart Grid 2

Atag heat pump boiler

SG1

SG2

Programming energy-saving routines for heat pumps

Konfigurer de energibesparende programmeringer til varmepumpen via Niko Home Control programmeringssoftware. For yderligere oplysninger henvises til https://guide.niko.eu/en/smnhc2/lv/solar-mode og https://guide.niko.eu/en/smnhc2/lv/peak-mode.

Du kan anvende følgende programmeringseksempel som en inspiration eller som et udgangspunkt: https://guide.niko.eu/en/penhc2/lv/making-a-bosch-heat-pump-respond-to-excess-electri

Det anbefales at konfigurere parametrene som følger:

Solcellefunktion

  • Niveau af overskydende solenergi, der aktiverer enheden (en af følgende muligheder):

    • 50 % af varmepumpens kompressoreffekt

    • 25 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Minimum aktiveringsvarighed: 1 time

Valgfrit: Definer det seneste starttidspunkt og varighed for at sikre, at enheden aktiveres før spidsbelastningstidspunktet.

Spidsbelastningsfunktion

  • Maksimalt effektforbrug (en af følgende muligheder):

    • 100 % af varmepumpens kompressoreffekt

    • 50 % af varmepumpens termiske kapacitet (ofte indeholder varmepumpens navn en reference til denne termiske kapacitet)

  • Maksimal målværdi: Det maksimale strømniveau, der bør få enhederne til at slukke

  • Type spidsbelastningsfunktion:

    • Prædiktiv (kapacitetstarif i Flandern)

    • Direkte

Niko programmering

Smart Grid forberedt status

Smart Grid forberedt udgangskontakt

Indstilling

Solcellefunktion

Forceret tænd

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Tændt (lukket)

Mere komfort

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Tændt (lukket)

Spidsbelastningsfunktion

Forceret sluk

Smart Grid forberedt 1

Tændt (lukket)

Smart Grid forberedt 2

Slukket (åben)

Normal funktion

Normal funktion

Smart Grid forberedt 1

Slukket (åben)

Smart Grid forberedt 2

Slukket (åben)


JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.