Niko Home Control is evolving into MOTIV Building Control. MOTIV is a new brand for intelligent building automation. Built on the trusted foundation of Niko Home Control, MOTIV solutions are designed to make buildings work more naturally for the people inside them. MOTIV helps professionals create smarter, more comfortable buildings. With technology that works quietly in the background. All existing Niko Home Control solutions remain fully compatible with MOTIV. Over time, the full portfolio will move to the MOTIV brand. Discover MOTIV at niko.eu/MOTIV
Hardware Manual
English Danish Dutch French German Slovak Swedish Polish
English Danish Dutch French German Slovak Swedish Polish

Installing the connected single switch, Zigbee®, Swiss line

Signal range

The point-to-point indoor range is ± 10 m. In open spaces, the RF range reaches 30 m. The meshing capability of 230 V powered Zigbee® devices can extend the RF range.

For more information see Zigbee® network principle.

The maximum point-to-point RF range of the connected switch to a Zigbee® receiver depends on:

  1. The materials used in the building or room,

  2. The indoor position of the connected switch, Zigbee®, and

  3. Sources of interference.


Materials and obstructions

Radio waves can be attenuated by materials inside a building or room.

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM410-00099-009.png

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM410-00099-010.png

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM410-00099-011.png

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM410-00099-012.png

Wood, plaster, uncoated, without metal

Brick, concrete

Ferroconcrete, lightweight hollow walls filled with insulating wool on metal foil, metallic heating insulation sheets, metallic surfaces, glass with a metal coating, floor heating systems, metal faceplates

Confined metal space

Loss: 5-20%

Loss: 20-40%

Loss: 40-90%

Loss: 90-100%

A human body can obstruct the Zigbee® radio path since its operating frequency band (2.4 GHz) resonates well with water particles. The Zigbee® meshing capability will generally remain intact after a radio path distortion, but take caution when a lot of people, or an object containing large volumes of water (e.g. an aquarium), are located in a room.

Position

Avoid installing the Zigbee® device:

  • In a narrow room with thick walls,

  • On the same wall as another Zigbee® repeating or receiving node,

  • Close to the ground (the recommended mounting height is 110 cm),

  • On a metal or moist surface or in a damp environment, or

  • In so-called 'dead spots', caused by radio reflections from nearby conductive materials or obstacles such as, metal cupboards, doors with a metallic foil or items containing water (e.g. aquariums).

Sources of interference

A Zigbee® connected switch is generally not disrupted by low-power electronic devices (e.g. DECT telephones, smartphones, WLAN routers, analogue radios, electronic ballasts, controllers, TVs, videos, computers, remote controls), and vice versa. Zigbee® is a robust and reliable RF technology thanks to its meshing capability and ability to capture radio telegrams from noisy environments.
Mind that a high-power electronic device in a room may interfere with the radio telegrams of a connected switch. Should this occur, identify the interfering source and remove it. If removal is not possible, consider relocating the connected switch or add a Zigbee® repeating node (e.g. a 230 V powered Niko Zigbee® device).

Wiring scheme

Switch off the mains.

Manual use

Connected use

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-004.png

This product must be secured with a miniature circuit breaker (MCB) of max. 16 A in the electrical cabinet. The MCB rating is limited by national installation rules

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-005.png

This product must be secured with a miniature circuit breaker (MCB) of max. 16 A in the electrical cabinet. The MCB rating is limited by national installation rules

  • All mechanical push-button extensions wired to the same terminal, will show the same behaviour (either the standard behaviour of the actor or a programmed behaviour). It is not possible to configure the behaviour of these extension switches separately. The maximum total wire length for all extension buttons connected to the Zigbee® switch is 50 m.

  • Also respect a minimum distance of 2 m between a Zigbee device (including the smart hub) and another RF transmitter (for example a Wi-Fi device) or devices such as motors, pumps, electronic LED transformers, solar panel inverters, home battery storage ...

Installation of the connected single switch, Swiss line

Note that the installation of a flush-mounting box and the electrical wiring is required prior to installing the connected Zigbee® device. For more information, check the Specifications on Connected single switch, Zigbee®, 10 A, Swiss line.

To install the connected single switch, proceed as follows:

Switch off the mains.

Step

Action

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-007.png

  • Insert only 1 electrical wire (1.5 – 2.5 mm²) per terminal

  • Apply a wire stripping length of 8 - 10 mm

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-008.png

  • Mount the connected switch, Zigbee® in a wall-mounting box with a minimum depth of 40 mm (cabling space included) and a screw distance of 60 mm. The wall-mounting box is to be installed at a recommended height of 110-120 cm above the final floor level

  • Use screws to fix the Zigbee® device to the wall-mounting box 

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-009.png

  • Attach a faceplate of the Feller EDIZIOdue colore series 

https://s3-eu-west-1.amazonaws.com/guideimages/HWScreenshots/V2.0/EN/PM101-72111-41-010.png

  • Press the faceplate evenly

  • The connected switch only switches the L-wire towards its pole contact. The N-wire will not be switched