Niko prepares its manuals with the greatest care and strives to make them as complete, correct and up to date as possible. Nevertheless, some deficiencies may subsist. Niko cannot be held responsible for this, other than within the legal limits. Please inform us of any deficiencies in the manuals by contacting Niko customer services at support@niko.eu.


Applicability

This link takes you to the product page. There, you will find detailed specifications, all compatible articles, certificates of CE-marking, etc.

This online manual is applicable to the following product(s):


Operation and use

Wiring

This product must be secured with a miniature circuit breaker (MCB) of max. 16 A in the electrical cabinet. The MCB rating is limited by national installation rules.

230 V – OFF / DALI power – OFF

The product acts as standalone detector in the following configuration:

Wiring

* Products that are used in the DALI zones must be secured with a miniature circuit breaker (MCB) as specified by their supplier. The connection to the DALI zones in this wiring diagram purely serves as an example.

The product acts as master detector in the following configuration:

Wiring

* Products that are used in the DALI zones must be secured with a miniature circuit breaker (MCB) as specified by their supplier. The connection to the DALI zones in this wiring diagram purely serves as an example.

Compatible secondary detectors

Mounting method

353-652021, 353-752021, 353-852011

Surface mounting

353-651021, 353-751021

Flush mounting (SnapFit)

353-650021, 353-750021

Flush-mounting box


Detection area

Detection area

Mounting height

Mounting height

A Walking

Walking

B Across

Across

C Towards

Towards

4.0 m

ø 18 m

ø 18 m

ø 11 m

8.0 m

ø 35 m

ø 33 m

ø 23 m

12.0 m

ø 53 m

*

ø 13 m

* Not specified

Measured according to EN/IEC 63180


Dimensions

Dimensions

Installation

ATTENTION!

Do not separate the sensor and actor part. Both parts must have the same MAC address:

ATTENTION

230 V – OFF / DALI power – OFF

Step 1

Installation step

Step 2

Installation step

Step 3

Use the wiring diagram to connect the wires correctly.

Installation step
Installation step

Step 4

a

b

Installation step
Installation step

Step 5

a

b

Installation step
Installation step

* A lens cover is optional. Check compatibility in the specification of the lens cover at www.niko.eu


Dismantling

230 V – OFF / DALI power – OFF

a

b

Dismantling
Dismantling

App settings

230 V – ON / DALI power – ON

  1. Download the app on Google Play (Android) or in the App Store (iOS)

  2. Enable Bluetooth® on your mobile device.

  3. Open the app “Niko detector tool” on your mobile device.

  4. Change the settings to your liking.

Setting

Luminosity

Delay

Factory settings

Switch ON/OFF

500 lux

15 min


LED behaviour

230 V – ON / DALI power – ON

Green LED on

Green LED continuous on

Connection OK

Green LED breathing

Green LED breathing

Connection OK, overrule ON

Green LED flashing

Green LED flashing

Warming up*

Wait

Red LED continuous on

Error

More info:

detector tool app

Detector tool app

Red LED breathing

Red LED flashing

Warning

Blue LED flashing

Blue LED flashing

Walk test active

* When Bluetooth® communication is disabled, the green LED does not flash while warming up.


Troubleshooting

Problem

Possible cause

Proposed solution

Load does not turn on

The wiring is not correct

Check the wiring scheme

The ambient light is too strong

Check the response value luminosity and raise the value if necessary

Load does not turn off

The switch-off delay is too long

Check the switch-off delay and shorten the delay if necessary

The detector receives false triggers

Check for any objects that may cause false triggering and remove them from the detection range or lower the sensitivity

App cannot connect to the detector

Bluetooth® has been disabled on your mobile device

Enable Bluetooth® on your mobile device


Legal information

Support & Contact

nv Niko sa
Industriepark West 40
9100 Sint-Niklaas, Belgium

http://www.niko.eu

+32 3 778 90 80
support@niko.eu

Warnings regarding installation

The installation of products that will permanently be part of the electrical installation and which include dangerous voltages, should be carried out by a qualified installer and in accordance with the applicable regulations. This user manual must be presented to the user. It should be included in the electrical installation file and it should be passed on to any new owners. Additional copies are available on the Niko website or via Niko customer services.

CE marking

This product complies with all of the relevant European guidelines and regulations. For radio equipment Niko llc declares that the radio equipment in this manual conforms with the 2014/53/EU directive. The full text of the EU declaration of conformity is available at https://www.niko.eu under the product reference, if applicable.

Environment

This product and/or the batteries provided cannot be disposed of in non-recyclable waste. Take your discarded product to a recognised collection point. Just like producers and importers, you too play an important role in the promotion of sorting, recycling and reuse of discarded electrical and electronic equipment. To finance the rubbish collection and waste treatment, the government levies recycling charges in certain cases (included in the price of this product).

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.