Skip to main content
Skip table of contents

Touchscreen

This touchscreen does not support access control. To be able to use access control with the Niko Home Control installation, use touchscreen 2 (550-20101). Consult Touchscreen 2 for more information.
This touchscreen cannot be used in installations with a connected controller light (550-00002).

Description

The Niko Home Control touchscreen offers residents a user-friendly interface to operate all functions within their Niko Home Control installation. The symbol displayed next to each action represents the current status of that action. In addition, the touchscreen provides a detailed overview of the electricity, gas and water consumption in the home, provided that these functions have been included in the installation.

Overview

Operation

The symbols on the touchscreen are used by the resident to operate the functions that you assigned while programming the installation. The resident can also use the touchscreen to request more information about the electricity, gas and water consumption in the home.

Using the touchscreen

1    Touch the touchscreen.

The start screen will appear. If you do not touch the screen during 30s, the display will be dimmed to reduce energy consumption.

2    Touch the corresponding tab to select “control”, “favourites”, “energy” or “settings".


Using the “control” tab

1 Select the “control” tab.


2    Select the location of your choice.


3    Select the function you wish to activate or deactivate.


Using the “favourites” tab

 To be able to use favourites, these favourites must have been entered first via the “settings” tab.

1    Select the “favourites” tab.

2   Select the function you wish to control.



Using the “energy” tab


  • The installation must be fitted with an electricity measuring module (see Electricity measuring modules) or a pulse counter (see Pulse counter) to be able to display the measuring data for gas, water and electricity.
  • If you are only using a pulse counter, live data for gas, water and electricity consumption will not be available.


1    Select the “energy” tab.

2    Select the measurement you wish to see: electricity, gas or water.

3    Select a period: live, day, week, month or year.

4    Select the display for the chosen period: consumption or cost (you cannot choose a display in EUR for a live measurement).


Using the “settings” tab

1    Select the “settings” tab.


2   
Do one of the following: 

  • Select “control” to select different symbols for the various locations.
  • Select “favourites” to add or remove actions from the list of favourites.
  • Select “system info” to view the system information.
  • Select “alarms” to consult the log book of notifications and alarms.


Installation


  • Connect the touchscreen with the RJ45 port 1, 2 or 3 of the connected controller. Use a twisted pair cable (preferably a shielded FTP or STP). Both the touchscreen and the connected controller are equipped with a RJ45 port. Therefore the RJ45 connectors must be attached to the cable to connect the connected controller on the one side and the touchscreen on the other, or you can make use of a cable with pre-mounted RJ45 connectors.
  • The touchscreen can be supplied with power using Power over Ethernet (PoE) via the same twisted pair cable, for which you use the Niko PoE power supply (550-00501). Alternatively, you can provide a separate power supply cable, which you connect to a separate 24 Vdc power supply module in the electrical cabinet. In that case, you will need a 24 V power supply cable such as an SVV, JYSTY, TPVF or UTP cable in addition to the twisted pair cable.


Connection  diagrams

Take into account the dimensions of the mounting bracket and the touchscreen in the images below to determine the exact location of the touchscreen on the wall.

Horizontally, the centre of the flush-mounting box must be at a distance of at least 130 mm from other walls, doors, etc.



  • Mount the touchscreen:
    • at eye level for optimum visibility (± 150 cm).
    • Do NOT mount the touchscreen: in direct sunlight
    • within the immediate vicinity of a fireplace, heater, or any other heat-generating source.
    • in damp locations.
  • The touchscreen itself is not suitable for flush mounting. Mount the touchscreen onto the wall using a standard flush-mounting box with a depth of at least 40 mm.
  • A total of ten touchscreens, smartphone or PC applications can be used per installation.




Use a drill (with a 6 mm diameter) to drill a hole of 40 mm for each connector. If you are drilling in wood, you will not need to use the connectors, and only a drill hole of 20 mm with a 3 mm diameter will be required.

Follow the steps below to mount the touchscreen:

1    Screw the mounting brachet onto the wall using the four screws and connectors supplied.


  • Mount the mounting brachet in a central position on top of the flush-mounting box.
  • Make sure the mounting plate is level.
  • The unevenness of walls cannot exceed 2 mm.


2    Connect the green screw connector supplied to the 24V power supply cable while observing the polarity as indicated on the back of the touchscreen.


If you are using a PoE power supply, you do not need a separate 24V power supply cable.

Only use the Niko PoE power supply type IEEE802.3af. This power supply provides voltage via the free pairs.

The green screw connector supplied (24V power supply) is suitable for a maximum copper diameter of 1.5 mm².


3    Mount a RJ45 connector on the twisted pair cable (UTP, STP or FTP) according to T568B.

4    Place the RJ45 connector and, if applicable, the 24V power supply cable, to the touchscreen.

5   Hang the touchscreen onto the mounting brachet and press it down against the wall in one smooth motion.

6    Tighten the touchscreen using the hexagon key supplied and remove the protective foil.



Programming the touchscreen


  • Add the touchscreen at the beginning of the project.
  • The touchscreen can display a maximum of 256 actions across 100 locations.
  • Several touchscreens used in one single installation cannot be programmed differently.


When you add the touchscreen to the project of the installation via the programming software, all pre-programmed actions will automatically be linked to the touchscreen.

The programming software allows you to create locations and link actions to each location. This will give you a better overview of the home. If an action is not linked to a location, the software will link the action to a virtual location. When all actions have been linked, click the touch icon to open the overview. In this overview, you can remove any actions that you do not want to be displayed on the touchscreen.

Touchscreen  maintenance

Use a soft dry or slightly damp cloth to clean the touchscreen. Do not use detergents or other cleaning agents.

Troubleshooting

 

Problem

Possible cause

Solution

Nothing is displayed on the screen.

Communication error

Check whether network communication is possible between the touchscreen and the connected controller.

You cannot operate the installation.

Reset the touchscreen.

Use an unfolded paperclip to press the reset button. There is no need to disassemble the touchscreen.

Technical data

Touchscreen

  • cannot be used in installations with a connected controller light (550-00002)
  • power supply voltage: 24 V DC (± 10 %) (SVV, JYSTY, TPVF, UTP, etc.) or Power over Ethernet (PoE) (UTP, STP, FTP) (48 V Vdc)
  • electricity consumption: 300 mA (24 Vdc) or 150 mA (PoE 48 Vdc)
  • ambient temperature:
    • in operation: 5 - 40 °C
    • storage and transport: -10 - 65 °C
  • ethernet connection speed: 10 - 100 Mbit/s
  • in conformity with EN 60950-1 + A11
  • CE marked
  • dimensions: 140 x 200 x 22 mm (H x W x D)
  • screen size: 7”
  • screen resolution: 800 x 480
  • weight: 934 g (excluding connectors and screws)


PoE power supply

  • suitable for touchscreen (550-20100), touchscreen 2 (550-20101) and external video unit (550-22001, 550-22002, 550-21001, 550-21002 and 550-21004)
  • type IEEE 802.3af
  • input voltage: 96 - 264 Vac
  • output voltage: 48 V
  • output power: 15.4 W
  • data in via RJ45 port
  • data and power supply out via RJ45 port
  • indication LEDs:
    • LED 1 (ON): green if correct input voltage
    • LED 2 (FAULT): red if error message
    • LED 3 (CONNECT): green if correct detection and connection
  • operating temperature: 0 – 40 °C
  • storage temperature -25 – 65 °C
  • dimensions: 36 x 65 x 140 mm (H x W x D)
  • CE marked



JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.