This step-by-step plan shows you how to add electricity metering to your installation in the Niko Home Control software.

For software version 1.9 or newer, there are additional options; see 

Electricity reading on eco-display from software version 1.9 onwards

.

The starting point for this step-by-step plan is a project for which the Project information has already been entered, for which a drawn or uploaded plan is available and to which several inputs, outputs and actions have already been added.

If you do not yet have a project, follow the steps in Add a new project and thereafter in Drawing a plan or Upload a background image.

Go to Creation in the menu at the top of the screen.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/023-v1816421-001.png

Click on add an input.

On the left, you now see the plan of the home and on the right is a selection list.

Click on electricity reading in the selection list.

The icon appears on the plan.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/023-v1816421-002.png

Drag the icon to a place on the plan that you consider logical and convenient.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/023-v1816421-003.png

Indicate whether the reading is a global reading, a consumption sub-reading or a yield sub-reading. Also indicate the type of reading.

Reading options: Global reading is shown as a total on the eco-display, on the touchscreen and in the app. Sub-readings are shown individually. A yield reading, for example, can be generated from solar panels. Yield readings are always shown as negative values relative to the other readings.


Reading type: Depending on the electrical installation, a single- or a triple-phase reading is made. These options require different modules. It is also possible to load readings via pulse counter.

Click save

The pop-up window closes.

Click save.

The electricity reading settings are saved.

Click on add an input.

On the right, you now see a selection list.

Click on eco-display in the selection list.

The icon appears on the plan.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/023-v1816421-004.png

Drag the icon to the right place on the plan.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/023-v1816421-005.png

Click save.

You return to the start screen of the Creation step.

Now continue with Cabinet set-up and Realisation.

The choice of module in the electrical cabinet depends on the type of reading.       
- Single-phase: Electricity metering module with 1 channel or with 3 channels.
- Triple-phase: Electricity metering module with three channels.
- Pulse: Pulse counter.