Skip to main content
Skip table of contents

Hitachi: Energy optimisation via wired connection (SG Ready contacts)

What do you need?

Niko requirements

Your Niko Home Control installation meets the following requirements:

Depending on the basic modules of your Niko Home Control installation, you need to install the following additional products:

Required additional products

Reference numbers

Connected controller

Switching module with two outputs

550-00103 or

550-00106

Connected controller with a wireless bridge

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721X2

Wireless smart hub

Connected double switch

The connected double switch can be placed on a DIN rail using a modular holder (e.g. Legrand 412950)

552-721X2

Hitachi requirements

Your system meets the following requirements:

  • It is a heat pump or heat pump boiler with Smart Grid Ready contacts.

  • It is configured to allow correct Smart Grid Ready contact use.

Your system is one of the following Hitachi products*

Potential-free contacts

230 V contacts

Heat pumps

  • Yutaki

  • Hisense Hi-Therma modellen

-

Heat pump boilers

  • Yutampo

-

*Consult the website of the supplier for detailed specifications and the latest products.

Wiring diagrams

Connecting heat pumps

Via potential-free contacts:

Switching module

Connected double switch

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

Smart Grid 1 and 2 (as indicated in the wiring diagrams) correspond to the the following Smart Grid Ready contacts on your heat pump:

Smart Grid 1

Smart Grid 2

Hitachi heat pump

SG-1

SG-2

Connecting heat pump boilers

Via potential-free contacts:

Switching module

Connected double switch

Wiring diagram Bus Potential free
Wiring diagram Potential free

*230V to potential-free contact module (e.g. Finder 22.32.0.230.1xx0)

Smart Grid 2 (as indicated in the wiring diagrams) corresponds to the the following Smart Grid Ready contact on your heat pump boiler:

Smart Grid 1

Smart Grid 2

Hitachi heat pump boiler

SG-1

SG-2

Programming energy-saving routines for heat pumps

Configure the energy-saving routines for the heat pump via the Niko Home Control programming software. For more information, see https://guide.niko.eu/en/smnhc2/lv/solar-mode and https://guide.niko.eu/en/smnhc2/lv/peak-mode.

You can use the following programming example as inspiration or as a starting point: https://guide.niko.eu/en/penhc2/lv/making-a-bosch-heat-pump-respond-to-excess-electri

It is advised to configure the parameters as follows:

Solar mode

  • Level of excess solar energy that activates the device (one of the following options):

    • 50 % of the power of the heat pump compressor

    • 25 % of the thermal capacity of the heat pump (often the name of the heat pump contains a reference to this thermal capacity)

  • Minimum activation duration: 1 hour

Optionally: Define the latest start time and duration to ensure that the device is activated before the peak hours.

Peak mode

  • Maximum power consumption (one of the following options):

    • 100 % of the heat pump compressor power

    • 50 % of the thermal capacity of the heat pump (often the name of the heat pump contains a reference to this thermal capacity)

  • Peak target value: the maximum power level that should trigger the devices to turn off

  • Peak mode type:

    • Predictive (capacity tariff in Flanders)

    • Direct

Niko routine

Smart Grid Ready status

Smart Grid Ready output contact

Setting

Solar mode

Forced on

Smart Grid Ready 1

On (closed)

Smart Grid Ready 2

On (closed)

Enhanced comfort

Smart Grid Ready 1

Off (open)

Smart Grid Ready 2

On (closed)

Peak mode

Forced off

Smart Grid Ready 1

On (closed)

Smart Grid Ready 2

Off (open)

Normal mode

Normal operation

Smart Grid Ready 1

Off (open)

Smart Grid Ready 2

Off (open)