Water and gas readings from software version 1.9 onwards

This step-by-step plan shows you how to add water and gas measuring to your installation in the Niko Home Control software for version 1.9 and newer.

The starting point for this step-by-step plan is a project for which the Project information has already been entered, for which a drawn or uploaded plan is available and to which several inputs, outputs and actions have already been added.

If you do not yet have a project, follow the steps in Add new project and thereafter in Draw a plan or Upload a background image.

Go to Creation in the menu at the top of the screen.

Click on add an input.

On the left, you now see the plan of the home and on the right is a selection list.

Click on water reading in the selection list in the right-hand section of the screen.

The icon appears on the plan.

Drag the icon to a place on the plan that you consider logical and convenient.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.

Under name on eco-display, assign the reading a recognizable name. This name will be shown on the eco-display and is limited in length to 14 characters. If you do not enter a name here, the eco-display will show only the water reading icon without any name.

Tip: Check the name on the eco-display; some characters are less legible than others and too many characters makes the display too cluttered.

Indicate whether the reading is a global reading or a consumption sub-reading. Up to 5 water sub-readings can be created, but only 1 global reading for water is possible. Set the desired reading scale.

Reading options: Global reading is shown as a total on the eco-display, on the touchscreen and in the app. Sub-readings are shown individually. 

Click save.

The pop-up window closes.

Click save.

The water reading settings are saved.

Click on gas reading in the selection list in the right-hand section of the screen.

The icon appears on the plan.

Drag the icon to the right place on the plan.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.

Under name on eco-display, assign the reading a recognizable name. This name will be shown on the eco-display and is limited in length to 14 characters. If you do not enter a name here, the eco-display will show only the gas reading icon without any name. 

Tip: Check the name on the eco-display; some characters are less legible than others and too many characters makes the display too cluttered.

Indicate whether the reading is a global reading or a consumption sub-reading. Up to 5 gas sub-readings can be created, but only 1 global reading for gas is possible. Set the desired reading scale.

Reading options: Global reading is shown as a total on the eco-display, on the touchscreen and in the app. Sub-readings are shown individually. 

Click save.

The pop-up window closes.

Click save.

The gas reading settings are saved.

Click eco-display in the selection list to add it to the installation.

The icon appears on the plan.

Drag the icon to the right place on the plan.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.


If you want only the global readings to appear on the eco-display, then select default under mode. These were in fact the same readings that were shown in installations with software versions older than 1.9.

Select manual under mode if you want a selection of all of the readings to appear on the eco-display. You select the desired energy readings from the uppermost list by clicking on the X in the relevant line. Then click on + to add this reading to the list below it. A maximum of 10 readings can be added to this list and therefore be displayed on the eco-display. You can change the position of a reading in the list by clicking on the arrows at the end of the line and dragging, and you can delete a reading from the list by clicking on the red X at the end of the relevant line.

If you then click on default under mode, the settings that were created under manual mode remain saved in the background. They will not be lost; they are simply re-selected when you click on manual mode again. 

Click save.

You return to the start screen of the Creation step.

Now continue with Cabinet set-up and Realisation.

For the water reading, add a pulse counter to the image of the cabinet to be set up. In the assign tab, link the water reading to one of the pulse counter outputs.