Software Manual Niko Home Control I

Water and gas readings before software version 1.9

This step-by-step plan shows you how to add water and gas metering to your installation in the Niko Home Control software.

For software version 1.9 or newer, there are additional options; see 

Water and gas readings from software version 1.9 onwards

.

The starting point for this step-by-step plan is a project for which the Project information has already been entered, for which a drawn or uploaded plan is available and to which several inputs, outputs and actions have already been added.

If you do not yet have a project, follow the steps in Add a new project and thereafter in Drawing a plan or Upload a background image.

Go to Creation in the menu at the top of the screen.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/025-v1816421-001.png

Click on add an input.

On the left, you now see the plan of the home and on the right is a selection list.

Click on water reading in the selection list in the right-hand section of the screen.

The icon appears on the plan.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/025-v1816421-002.png

Drag the icon to a place on the plan that you consider logical and convenient.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/025-v1816421-003.png

Set the desired reading scale.

Click save.

The pop-up window closes.

Click on gas reading in the selection list in the right-hand section of the screen.

The icon appears on the plan.

Drag the icon to the right place on the plan.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click on modify basic settings.

A pop-up window appears.

Set the desired reading scale.

Click save.

The pop-up window closes.

Click eco-display in the selection list to add it to the installation.

The icon appears on the plan.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/025-v1816421-004.png

Drag the icon to the right place on the plan.

Assign the input a recognizable name.

Select a location from the selection list or add a location if the location has not previously been defined.

Click save.

You return to the start screen of the Creation step.

https://s3-eu-west-1.amazonaws.com/guideimages/ScreenShots/V1.0/EN/025-v1816421-006.png

Now continue with Cabinet set-up and Realisation.

For the water reading, add a pulse counter to the image of the cabinet to be set up. In the assign tab, link the water reading to one of the pulse counter outputs.