Energy (diagnostics)

Starting point

Description of the Energy tab

The Energy tab shows the status of:

The tab contains static information, click Refresh data to reload the page.

 

Click the button Export data to create a .csv file that contains your daily and quarterly energy consumption.

Digital meter P1 connection

The section of the digital meter P1 connection contains the following components:

Component

Description

Connection

Connection indicator:

  • connected: the digital meter is connected with the P1 cable to the wireless smart hub

  • disconnected: the digital meter is not connected to the wireless smart hub

Last communication

Time stamp of the last communication of the digital meter with the wireless smart hub

Protocol

  • DSMR 2.2, 3, 4 or 5 (NL)

  • Fluvius, Ores, Resa, Sibelga (BE)

Invalid/total amount of message

Gives an idea of the communication status between the digital meter and the wireless smart hub:

  • high number of invalid messages = poor communication

  • low number of invalid messages = good communication

Available measurements

  • Type of data available on the P1 port

  • Serial number of your digital meter

Solar panel inverter

The section of the solar panel inverter contains the following components:

Component

Description

Connection

Connection indicator:

  • connected: the solar panel inverter is connected to the connected controller or the wireless smart hub

  • disconnected: the solar panel inverter is not connected to the connected controller or the wireless smart hub

Last communication

Time stamp of the last communication of the solar panel inverter with the connected controller or the wireless smart hub

Vendor

SMA, vendor supported as from v2.10

Serial number

Serial number of the solar panel inverter

Error code

Information for your PV installer or SMA in case of problems

ModBus connection

Information for your PV installer or SMA in case of problems

Installer password

Information for your PV installer or SMA in case of problems

Energy measurements

The section of the energy measurements contains the following components:

Component

Description

Arrow

Click the arrow next to the energy measurement you want to diagnose.

Name

The name or screen name of the measurement in the programming software. 

Live value

The live energy measurement is a static value.

Click Refresh data to reload the value.

For a global reading, the value can be positive (consuming energy from the grid) or negative (injecting energy into the grid).

For a sub-reading, the value should always be a positive value. If the value is negative, you have to set the parameter clamp measurement direction (of a channel) of the energy reading control to inverted and upload the configuration file to the installation, or physically switch the direction of the measuring clamp in the cabinet.

The value of a smart plug or a connected switching socket outlet is always positive.