Manual NHC Nikobus interface
Situation
These steps show how to control a Nikobus output using Niko Home Control (part 1), and how to control a Niko Home Control output using Nikobus (part 2).
Starting point
The starting point in this example is a new project with no inputs or outputs. Of course, you can also start with an existing project.
Part 1: Controlling a Nikobus output using Niko Home Control.
Add a single push button
- Go to Creation in the menu bar at the top.
- Click on add an input.
In the left hand side of the screen, you can now see the plan of the home and, in the right hand side, a list of options. - Click on single push button.
- Drag the icon to the correct place on the plan.
- Give the input a name (e.g. Push button Entrance)
- Choose a location from the list of options or add a location if the location has not been previously defined (e.g. Entrance).
- Click on save to return to the Creation start screen.
Add a Nikobus Output
- Click on add an output.
In the left hand side of the screen, you can now see the plan of the home and, in the right hand side, a list of options. - Click on Nikobus output.
- Drag the icon to the correct place on the plan.
- Give the output a name (e.g. Light point entrance)
- Choose a location from the list of options or add a location if the location has not been previously defined (e.g. Entrance).
- Click on save to return to the Creation start screen.
Create an action 'Light entrance'
- Click on add an action. The action will appear as a text balloon on the plan.
- Drag the icon to a logical and appropriate place on the plan.
- Give the action a clear name, for example Light entrance.
- Choose a location from the list of options or add a location if the location has not been previously defined.
- Click on continue to go to the Players tab.
- Choose the single push button as the input.
- Choose the Nikobus output as the output.
- Click on continue to go to the Basic behaviour tab.
- Click on continue to go to the Conditions tab.
- Click on continue to go to the Time automation tab.
- Click on save to return to the Creation start screen.
Complete the Nikobus address in the NHC software.
- Go to the Nikobus configuration software.
- As an Input add a double generic control.
- Select the double generic control.
- Click on Address/Parameters.
- If necessary, retrieve the address of the component by clicking Retrieve! .
- Select and copy(Ctrl+c) the address of the component.
- Go to the Niko Home Control configuration software.
- Click on the Nikobus output.
- Paste(Ctrl+v) the address of the component in the Nikobus address field.
- Click on save.
- Go to the Nikobus configuration software.
- Make a new connection between a switch output and the generic control.
- You can now programme the Nikobus installation and the Niko Home Control installation and test their operation.
Part 2: Controlling a Niko Home Control output using Nikobus.
Add a Nikobus input
- Go to Creation in the menu bar at the top.
- Click on add an input.
In the left hand side of the screen, you can now see the plan of the home and, in the right hand side, a list of options. - Click on Nikobus input.
- Drag the icon to the correct place on the plan.
- Give the input a name (e.g. Nikobus push button living room)
- Choose a location from the list of options or add a location if the location has not been previously defined (e.g. Living room).
- Click on save to return to the Creation start screen.
Add a connected lamp
- Go to Creation in the menu bar at the top.
- Click on add an output.
In the left hand side of the screen, you can now see the plan of the home and, in the right hand side, a list of options. - Click on lamp.
- Drag the icon to the correct place on the plan.
- Give the output a name (e.g. Lamp living room)
- Choose a location from the list of options or add a location if the location has not been previously defined (e.g. Living room).
- Click on save to return to the Creation start screen.
Create an action 'Light living room'
- Click on add an action. The action will appear as a text balloon on the plan.
- Drag the icon to a logical and appropriate place on the plan.
- Give the action a clear name, for example Light living room.
- Choose a location from the list of options or add a location if the location has not been previously defined.
- Click on continue to go to the Players tab.
- Choose the Nikobus input as the input.
- Choose the connected lamp as the output.
- Click on continue to go to the Basic behaviour tab.
- Click on continue to go to the Conditions tab.
- Click on continue to go to the Time automation tab.
- Click on save to return to the Creation start screen.
Complete the Nikobus address in the NHC software.
- Go to the Nikobus configuration software.
- Add a single push button.
- Connect the double push button with an output of a switching module.
- Select the Nikobus push button.
- Click on Address/Parameters.
- If necessary, retrieve the address of the component by clicking Retrieve! .
- Select and copy(Ctrl+c) the address of the component.
- Go to the Niko Home Control configuration software.
- Click on the Nikobus input.
- Paste(Ctrl+v) the address of the component in the Nikobus address field.
- You can now programme the Nikobus installation and the Niko Home Control installation and test their operation.