LED | Reason | Action |
---|
|
| Normal operation |
|
| Firmware upgrade of the Danfoss Master controller is in progress. | Wait until the upgrade is finished. |
| There is a communication loss between the Danfoss IconTM Zigbee® module and the wireless smart hub. | - Execute a ping test. If the test fails, there might be a range problem.
- Put the devices closer together.
- Add a Zigbee repeater
- The wireless smart hub is not powered on. Power on the device.
- There is a problem with the Danfoss Icon Zigbee module. Contact your HVAC installer to replace the device.
|
| The Danfoss Master controller is not compatible with the Danfoss Icon Zigbee module. | Contact your HVAC installer. |
|
2 times /s for 30 s
| The Zigbee pairing of the Danfoss Icon Zigbee module with the wireless smart hub is in progress. | - Duration: 30 s
- Wait until the pairing is finished. The LED will light up green for a few seconds and will then switch off.
|
| The Danfoss Zigbee module and the wireless smart hub are out of range. | - Close the onboarding screen in the Niko Home app or the Address overview window in the Niko Home Control programming software.
- Check the distance between the module and the wireless smart hub.
- Put the devices closer together.
- Add a Zigbee repeater
- Perform a factory reset on the Danfoss Icon Zigbee module.
- When the problem is resolved, restart the onboarding/addressing process.
- When the problem is not resolved, contact your HVAC installer to replace the Danfoss Icon Zigbee module.
|
2 times /s for 30 s
5 times

| The Zigbee pairing started but failed. | - Close the onboarding screen in the Niko Home app or the Address overview window in the Niko Home Control programming software.
- Check if the wireless smart hub is powered on. If not, power on the device.
- Perform a factory reset on the Danfoss Icon Zigbee module.
- Check the distance between the module and the wireless smart hub.
- Put the devices closer together.
- Add a Zigbee repeater
- When the problem is resolved, restart the onboarding/addressing process.
|
| The onboarding process has not started. | Start the onboarding/addressing process before you pair the Danfoss Zigbee module with the wireless smart hub. |
|
| Ping test successful. |
|
| Ping test failed. | - There might be a range problem:
- Put the devices closer together.
- Add a Zigbee repeater
- The wireless smart hub is not powered on. Power on the device.
- There is a problem with the Danfoss Icon Zigbee module. Contact your HVAC installer to replace the device.
|